Ports & interfaces | |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
AC outlet types | Terminal |
Operational conditions | |
Operating relative humidity (H-H) | 0 - 95% |
Operating temperature (T-T) | 0 - 40 °C |
Packaging data | |
Bundled software | Winpower |
Battery | |
Number of batteries supported | 4 |
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Design | |
Form factor | Tower |
LED indicators | |
Product colour | Black |
Cooling type | Active |
Display type | LCD |
Features | |
Emergency Power Off (EPO) | |
Output power capacity | 10 kVA |
Noise level | 55 dB |
Input frequency | 45/66 Hz |
Output power | 9000 W |
Output voltage Total Harmonic Distortion (THD) | 2% |
Crest factor | 3:1 |
Input operation voltage (max) | 276 V |
Input operation voltage (min) | 110 V |
Output operation voltage (min) | 208 V |
Output operation voltage (max) | 240 V |
Input power factor | 0.99 |
Output voltage regulation | 1% |
UPS topology | Double-conversion (Online) |
EAN | 4260074976663 |
Warranty | 1 year |
Source: Icecat.biz |
A Online UPS always provide clean power and have a protection against all standard power problems in a network.
A Online UPS is build up with double- conversation technology. First, incoming AC power is converted into DC power and stored in a buffer. In the second step the buffered DC power is converted to AC power and made available for the loads. Doing so the UPS loads are isolated from incoming AC power (and all its problems) and fed by power generated by the UPS. The result is an always clean and stable output power.
Another advantage of this technology is the fact that there is no transfer time in case of a failure. Furthermore a Online UPS provides the most reliable voltage regulation which is typically within 2-3 percent of the standard voltage wave form. Online UPS offers USB port (RS-232) to connect to a multitude of operating systems for maintenance, monitoring voltage, power and battery status.
Online UPS are designed for all critical applications
- 10000VA Online UPS with 3 phase in / 1 phase out
- High Power Factor 0.9
- Terminal Outlet, EPO, MBS, USB, RS-232
- Parallel System Configuration / Parallel redundancy
- Optional SNMP card, Battery Pack, Modbus card, AS/400 Card, Charger
Estimated delivery: 14.01 - 20.01
Today: 10:00 - 18:00
Estimated delivery: 14.01 - 20.01
Today: 09:00 - 17:00
Estimated delivery: 14.01 - 20.01
Today: 10:00 - 18:00
Estimated delivery: 14.01 - 20.01
Today: 10:00 - 17:00
Estimated delivery: 14.01 - 20.01
Today: 10:00 - 18:00
Estimated delivery: 14.01 - 20.01
Today: 10:00 - 18:00
Estimated delivery: 14.01 - 20.01
Today: 10:00 - 18:00
Estimated delivery time: 14.01 - 20.01
Estimated delivery time: 14.01 - 19.01
Estimated delivery time: 15.01 - 20.01
Estimated delivery time: 15.01 - 20.01
Estimated delivery time: 15.01 - 19.01
Estimated delivery time: 15.01 - 19.01