Välj en eller flera funktioner för att söka efter produkter med samma specifikationer.Vikt & dimension | |
Vikt | 577 g |
Höjd | 145 mm |
Bredd | 120 mm |
Djup | 120 mm |
Strömtillförsel | |
Värmeavledningseffekt (TDP) | 140 W |
Förpackningens innehåll | |
Förpackningstyp | Låda |
Antal skruvar | 4 |
Design | |
Produktens färg | Svart, Silver, Vit |
Antal fläktar | 1 fläkt/-ar |
Antal värmerör | 3 |
Prestanda | |
Modell | Cooler |
Fläktdiameter | 12 cm |
Stödd processor uttag | LGA 1150 (uttag H3), LGA 1151 (uttag H4), LGA 1155 (Socket H2), LGA 1156 (Socket H), Socket AM2, Socket AM2 +, Uttag AM4, Socket FM1, Socket FM2 |
Lämplig placering | Processor |
Minsta luftflöde | 59 cfm |
Maximalt lufttryck | 1,65 mmH2O |
Ljudnivå (hög hastighet) | 25 dB |
Rotationshastighet (max) | 1600 RPM |
Rotationshastighet (min) | 300 RPM |
EAN | 4719692701169 |
Source: Icecat.biz |
Breaking Design Molds
CRYORIG H Series coolers feature our proprietary Hive Fin™ structure. This design allows for a combination of Jet Fin Acceleration™ and Turbulence Reduction, as well as strengthening structural strength of the fin stacks. Combined together, the Hive Fin™ design brings cool innovation.
Air Exhaust Acceleration Hot Air Cooled Fast
By utilizing a larger air intake and narrower air exhaust section on the fins, compresses the air to move faster while exiting the heatsink. Jet Fin Acceleration System™ carries the hot air out of the system faster and more efficiently.
Extreme Efficiency Turbulence Reduction System
Utilizing a bee hive shaped structure at the front air intake of the heatsink, lowers air turbulence and straightens out the airflow. Assisting airflow to move directly through the full length of the heatsink and carrying out hot air.
Air Exhaust Acceleration Hot Air Cooled Fast
By utilizing a larger air intake and narrower air exhaust section on the fins, compresses the air to move faster while exiting the heatsink. Jet Fin Acceleration System™ carries the hot air out of the system faster and more efficiently.
Extreme Efficiency Turbulence Reduction System
Utilizing a bee hive shaped structure at the front air intake of the heatsink, lowers air turbulence and straightens out the airflow. Assisting airflow to move directly through the full length of the heatsink and carrying out hot air.
Optimized Heatpipe Positioning Total CPU Coverage
The H7’s Heatpipe Convex-Align™ System allows for more heatpipes in a given area, optimized heatpipe placement in the copper base, and improved alignment with your CPU. With the Heatpipe Convex-Align™ System, each heatpipe functions to their maximum TDP capacity.
The H7’s Heatpipe Convex-Align™ System allows for more heatpipes in a given area, optimized heatpipe placement in the copper base, and improved alignment with your CPU. With the Heatpipe Convex-Align™ System, each heatpipe functions to their maximum TDP capacity.
Beräknad leverans: 09.12 - 11.12
Idag: 10:00 - 18:00
Beräknad leverans: 09.12 - 11.12
Idag: 09:00 - 17:00
Beräknad leverans: 09.12 - 11.12
Idag: 10:00 - 18:00
Beräknad leverans: 09.12 - 11.12
Idag: 10:00 - 17:00
Beräknad leverans: 09.12 - 11.12
Idag: 10:00 - 18:00
Beräknad leverans: 09.12 - 11.12
Idag: 10:00 - 17:00
Beräknad leverans: 09.12 - 11.12
Idag: 10:00 - 18:00
Beräknad leveranstid: 09.12 - 11.12
Beräknad leveranstid: 10.12 - 11.12
Beräknad leveranstid: 09.12 - 10.12
Beräknad leveranstid: 10.12 - 11.12
Beräknad leveranstid: 10.12
Beräknad leveranstid: 10.12