Vikt & dimension | |
Vikt | 12,3 kg |
Miljökrav | |
Altitud vid drift | 0 - 3000 m |
Intervall för relativ operativ luftfuktighet | 0 - 95% |
Temperaturintervall (förvaring) | -15 - 45 ° C |
Temperatur vid drift | 0 - 40 ° C |
Fuktighet (förvaring) | 0 - 95% |
Höjd över havet i avstängt läge | 0 - 15000 m |
Batteri | |
Batteriteknik | Slutna blybatterier (VRLA) |
Laddningstid | 5 h |
Normal drifttid vid halv belastning | 15,7 min |
Normal drifttid vid full belastning | 5,5 min |
Hot-swap batteri | ![]() |
Övriga egenskaper | |
Gränssnitt | DB-9, RS-232 |
Produktstorlek (BxDxH) | 119 x 368 x 168 mm |
Utspänning (Volt) | 120 V |
Anslutningsdetaljer utgång | (4) NEMA 5-15R |
Anslutningsdetaljer ingång | NEMA 5-15P |
Ingångsspänning (Volt) | 120 V |
Design | |
Certifiering | CSA,FCC Part 15 Class A,UL 1778 |
Kabellängd | 1,83 m |
LED-indikatorer | ![]() |
Produktens färg | Grå |
Egenskaper | |
Hörbart larm | ![]() |
Nödstopp (EPO) | ![]() |
Uteffekt kapacitet (VA) | 0,62 kVA |
Energivärdering | 412 J |
Ljudnivå Lc IEC | 45 dB |
Ingångsfrekvens | 50/60 hz |
Uteffekt | 390 W |
EAN | 731304222620 |
Garanti | 1 år |
Source: Icecat.biz |
-Network manageable: Provides remote management of the UPS over the network.
-Audible alarms: Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
-Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
-Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance
-Serial Connectivity: Provides management of the UPS via a serial port.
-LED status indicators: Quickly understand unit and power status with visual indicators.
-InfraStruXure Manager compatible: Enables centralized management via the APC InfraStruXure® Manager.
-Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery.
-Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
-Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.
-Dataline Surge Protection: Provides protection of connected equipment from power surges on the data lines.
-Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances.
-Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.
-Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power.
-Cold-start capable: Provides temporary battery power when the utility power is out.
-Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced.
-Resettable circuit breakers: Enables a quick recovery from overload events.
Beräknad leverans: Ingen leverans information
Idag: 10:00 - 18:00
Beräknad leverans: Ingen leverans information
Idag: 09:00 - 17:00
Beräknad leverans: Ingen leverans information
Idag: 10:00 - 17:00
Beräknad leverans: Ingen leverans information
Idag: 10:00 - 18:00
Beräknad leverans: Ingen leverans information
Idag: 10:00 - 17:00